微油單螺旋式空壓機

單螺旋式 空壓機

單螺旋式空氣壓機規範

  • 馬力: 10 ~ 200 HP
  • 壓力: 7 ~ 9.5 kg / cm 2 G
  • 風量: 1.22 ~ 27 m 3 / min
單螺旋式空氣壓縮機,係由一支螺旋母轉子帶動二支閘門轉子,母轉子每迴轉一次,即有十二次的壓縮過程來提高壓力。轉子均無軸向。徑向推力及不平衡力,能將振動減少到最低程度,故軸承壽命長,噪音低之優點。
  • 轉速低,故障機率幾乎等於零。
  • 微電腦控制,具自我診斷偵測、維護指示及保護裝置。
  • 附省電的容量調整裝置 0~100% 控制。
  • ZU 型提供完全無油的壓縮空氣。

ZA series Line up

15kw~75kw
Model ZV15AS3-R Increasing type
Items Unit ZV22AS3i-R ZV37AS3i-R
Delivered air pressure (Pressure adjustment range) MPa
(kg/cm 2 )
0.5 - 0.93 (5.5 - 9.5) / 0.7 (7.1)
Pressure control method Constant pressure control by inverter (Rotation speed control)
Number of revolutions (nominal) min -1 3500 4200 4000
Free air delivery m 3 /min 2.6 3.8 (4.5) ※ 6.4 (7.4) ※
Capacity control method Suction restriction type, automatic start / stop selection energy saving AUCS selection
Intake air pressure & temperature Atmospheric pressure (0 to 40 o C)
Main motor power KW 15 22 37
Power source voltage 50/60Hz,V 200 220 380 415 400 440V
Motor type *1 Totally-enclosed, permanent magnet rotor type three phase synchronized
Starter Inverter start
Drive system Direct coupled motor
Cooling system Air-cooling
Fan motor power KW 0.9 1.8
Oil fill ration L 15 20
Chamber capacity L 26 32
Protection equipment Discharge temperature, fan motor overload, power supply reversed phase, Inverter error, Fan error, Dryer error, water stop relay
Dryer Air dew point at outlet o C 10 (Under application of pressure)
Power consumption 50/60Hz,
KW
0.53/0.64 1.1/1.2 1.5/1.8
Cooling medium R407C
Discharge pipe diameter R 1 1 1/2
WidthxLengthxHeight(Body) mm 1350x750x1200 1350x850x1200 1995x950x1420
Total mass(Dry state)(Dryer less) kg 540 {470} 540 {460} 840 {700}
Noise level dB. A 57 57 59
WidthxLengthxHeight(Body)
Dryer less
mm 1030x750x1200 1030x850x1200 1415x950x1420
Model Increasing type
Items Unit ZV55AS3i-R ZV75AS3i-R
Delivered air pressure (Pressure adjustment range) MPa
(kg/cm 2)
0.5 - 0.93 (5.5 - 9.5) / 0.7 (7.1)
Pressure control method Constant pressure control by inverter (Rotation speed control)
Number of revolutions (nominal) min -1 2954 4200
Free air delivery m 3 /min 9.5 (11.0) ※ 13.0 (14.0) ※
Capacity control method Suction restriction type, automatic start / stop selection energy saving AUCS selection
Intake air pressure & temperature Atmospheric pressure (0 to 40 o C)
Main motor power KW 55 75
Power source voltage 50/60Hz,V 200 220 380 415 400 440V
Motor type Totally-enclosed, permanent magnet rotor type three phase synchronized
Starter Inverter start
Drive system Direct coupled motor
Cooling system Air-cooling
Fan motor power KW 3.0
Oil fill ration L 60
Chamber capacity L 158
Protection equipment Discharge temperature, fan motor overload, power supply reversed phase, Inverter error, Fan error, Dryer error, water stop relay
Dryer Air dew point at outlet o C 10 (Under application of pressure)
Power consumption 50/60Hz,
KW
2.1/2.5 2.9/3.6
Cooling medium R407C
Discharge pipe diameter R 2
WidthxLengthxHeight(Body) mm 2325x1200x1700 2803x1200x1700
Total mass(Dry state)
(Dryer less)
kg 1440 {1270} 1740 {1430}
Noise level dB. A 67 71
WidthxLengthxHeight(Body)
Dryer less
mm 1885x1200x1700 2060x1200x1700
Model Increasing type
Items Unit ZV55WS3i-R ZV75WS3i-R
Delivered air pressure (Pressure adjustment range) MPa
(kg/cm 2 )
0.5 - 0.93 (5.5 - 9.5) / 0.7 (7.1)
Pressure control method Constant pressure control by inverter (Rotation speed control)
Number of revolutions (nominal) min -1 2954 3944
Free air delivery m 3 /min 9.5 (11.0) ※ 13.0 (14.0) ※
Capacity control method Suction restriction type, automatic start / stop selection energy saving AUCS selection
Intake air pressure & temperature Atmospheric pressure (0 to 40 o C)
Main motor power KW 55 75
Power source voltage 50/60Hz,V 200 220 380 415 400 440V
Motor type Totally-enclosed, permanent magnet rotor type three phase synchronized
Starter Inverter start
Drive system Direct coupled motor
Cooling system Water-cooling
Fan motor power KW 3.0
Oil fill ration L 60
Chamber capacity L 158
Protection equipment Discharge temperature, fan motor overload, power supply reversed phase, Inverter error, Fan error, Dryer error, water stop relay
Dryer Air dew point at outlet o C 10 (Under application of pressure)
Power consumption 50/60Hz,
KW
2.1/2.5 2.9/3.6
Cooling medium R407C
Discharge pipe diameter R 2
WidthxLengthxHeight(Body) mm 2325x1200x1700 2803x1200x1700
Total mass(Dry state)
(Dryer less)
kg 1440 {1270} 1740 {1430}
Noise level dB. A 67 71
WidthxLengthxHeight(Body)
Dryer less
mm 1885x1200x1700 2060x1200x1700
  • Caution : Dryer of low pressure specifications (Factory option) shall be separate type. Consult factory for dimension and total mass dryers.
  • Value in ※( ) is free air delivery of 0.39MPa specifications (Factory option).
  • ◎ For 400/440V specification (optional) , type ZVi22,37 shall mount the multi purpose motor.
  • *1 : Three phase squirrel cage type electric motor. Attached with flange leg, 2P totally-enclosed external.

Z&ZV SR series Line up

7.5kW/11kW
Model Z085SR Z086SR Z115SR Z116SR ZV08SR ZV11SR
Items Unit
Delivered air pressure MPa
(kg/cm 2 )
0.83 (8.5) / 0.93 (9.5) 0.7(7.1) /
0.93(9.5)
Free air delivery m 3 /min 1.2/0.94

1.8/1.44

1.2/0.94 1.8/1.44
Intake air pressure & temperature Atmospheric pressure (0 to 40 o C)
Capacity control method Power-saving AUCS Automatic start/stop selection Constant pressure control by inverter (Rotation speed control)
Main motor power KW 7.5 11 7.5 11
Power source voltage 50/60Hz,V 200 220 380 400 415 440V
Motor type 3-phase squirrel cage, 2P totally-enclosed external fan *2
Starter Direct ON start Inverter start
Drive system Direct coupled motor
Cooling system Air-cooling
Fan motor power KW 0.4 0.9 0.4 0.9
Oil fill ration L 10
Chamber capacity L 23
Protection equipment Main motor overload, discharge temperature *3
Dryer Air dew point at outlet o C 10 (Under application of pressure)
Power consumption KW 0.53 0.63 0.53 0.63 0.53 / 0.63
Cooling medium R407C
Discharge pipe diameter R 3/4
WidthxLengthxHeight(Body) mm 995x750x1430
Total mass(Dry state)
(Dryer less)
kg 410{400} 430{405} 440{410} 460{430}
Noise level dB. A 53 55 53 55
  • 2 = 3-phase squirrel cage type electric motor, Attached with flange leg, 2P totally-enclosed external
  • 3 : Discharge temperature, fan motor overload, power supply reversed phase, Inverter error, Fan error, Dryer error

Z series Line up

15kW~37kW
Model Z155AS2-R Z156AS2-R Z225AS2-R Z226AS2-R
Items Unit
Delivered air pressure ※ MPa
(kg/cm 2 )

0.70(7.1) / 0.93( 9.5)

Free air delivery ※ m 3 /min 2.6 / 2.0 3.9(2.0) / 2.9
Intake air pressure & temperature Atmospheric pressure (0 to 40 o C)
Capacity control method Power-saving AUCS Automatic start/stop selection
Main motor power kW 15 22
Power source voltage 50/60Hz,V 200 220 380 400 415 440V
Motor type 3-phase squirrel cage, 2P totally-enclosed external fan
Starter Direct ON start 3 contactors, Y-
Drive system Direct coupled motor
Cooling system Air-cooling
Fan motor power KW 0.9
Oil fill ration ※ L 13(10) 15(13)
Chamber capacity ※ L 26(23) 26
Protection equipment Main & fan motor overload, discharge temperature, water stop relay(Water-cooling)
Dryer Air dew point at outlet o C 10 (Under application of pressure)
Power consumption ※ kW 0.53(0.49) 0.64(0.57) 1.1(0.49) 1.2(0.57)
Cooling medium R407C
Discharge pipe diameter ※ R 1(RC3/4)
WidthxLengthxHeight(Body) ※ mm 1350x750x1200 1350x850x1200
Total mass(Dry state)(Dryer less) kg 530 {470} 580 {530}
Noise level dB. A 57
WidthxLengthxHeight(Body)
Dryer less
mm 1030x750x1200 1030x850x1200
Model Z375AS2-R Z376AS2-R Z375WS2-R Z376WS2-R
Items Unit
Delivered air pressure ※ MPa
(kg/cm 2 )
0.70(7.1) / 0.93( 9.5)
Free air delivery ※ m 3 /min 6.5 / 5.2
Intake air pressure & temperature Atmospheric pressure (0 to 40 o C)
Capacity control method Power-saving AUCS Automatic start/stop selection
Main motor power kW 37
Power source voltage 50/60Hz,V 200 220 380 400 415 440V
Motor type 3-phase squirrel cage, 2P totally-enclosed external fan
Starter 3 contactors, Y-
Drive system Direct coupled motor
Cooling system Air-cooling Water-cooling
Fan motor power KW 1.8 0.05 0.08
Oil fill ration ※ L 20
Chamber capacity ※ L 32
Protection equipment Main & fan motor overload, discharge temperature, water stop relay(Water-cooling)
Dryer Air dew point at outlet o C 10 (Under application of pressure)
Power consumption ※ kW 1.5 1.8 1.5 1.8
Cooling medium R407C
Discharge pipe diameter ※ R 1 1/2
WidthxLengthxHeight(Body) ※ mm 1995x952x1420
Total mass(Dry state)(Dryer less) kg 940 {880} 860 {800}
Noise level dB. A 59
WidthxLengthxHeight(Body)
Dryer less
mm 1415x952x1420
※make (of an item) shll be the medium pressure (1.37MPa) specification ◎ Coolant volume (Water temperature 32 o C) 37kW : 65L/min

55kW~75kW

Model Z555AS
2-R
Z556AS
2-R
Z755AS
2-R
Z756AS
2-R
Z755AS
2H-R
Z756AS
2H-R
Items Unit
Delivered air pressure ※ MPa
(kg/cm 2 )

0.69(7) / 0.93( 9.5)

Free air delivery ※ m 3 /min 9.5/7.70 13.0/0.5
Intake air pressure & temperature Atmospheric pressure (0 to 40 o C)
Capacity control method Power-saving AUCS Automatic start/stop selection
Main motor power kW 55 75
Power source voltage 50/60Hz,V 200 220 380 400 415 440V 3000 3300
Motor type 3-phase squirrel cage,
2P totally-enclosed external fan
*4
Starter 3 contactors, Y- Rector
Drive system Direct coupled motor
Cooling system Air-cooling
Fan motor power KW 3.0
Oil fill ration ※ L 60
Chamber capacity ※ L 158
Protection equipment Main & fan motor overload, discharge temperature, reversed phase
Dryer Air dew point at outlet o C 10 (Under application of pressure)
Power consumption ※ kW 2.1 2.5 2.9 3.6 2.9 3.6
Cooling medium R407C
Discharge pipe diameter ※ R 2
WidthxLengthxHeight(Body) ※ mm 1990x1200x1700 2543x1200x1700 3338x1470x1700
Total mass(Dry state)(Dryer less) kg 1550[1450] 1850[1600] 2400[2200]
Noise level dB. A 67 71 73
WidthxLengthxHeight(Body)
Dryer less
mm 1550x1200x1700 1800x1200x1700 2595x1470x1700
Model Z555WS
2-R
Z556WS
2-R
Z755WS
2-R
Z756WS
2-R
Z755WS
2H-R
Z756WS
2H-R
Items Unit
Delivered air pressure ※ MPa
(kg/cm 2 )

0.69(7) / 0.93( 9.5)

Free air delivery ※ m 3 /min 9.5/7.70 13.0/10.5
Intake air pressure & temperature Atmospheric pressure (0 to 40 o C)
Capacity control method Power-saving AUCS Automatic start/stop selection
Main motor power kW 55 75
Power source voltage 50/60Hz,V 200 220 380 400 415 440V 3000 3300
Motor type 3-phase squirrel cage,
2P totally-enclosed external fan
*4
Starter 3 contactors, Y- Rector
Drive system Direct coupled motor
Cooling system Water-cooling
Fan motor power KW 0.08 0.12 0.08 0.12 0.08 0.12
Oil fill ration ※ L 60
Chamber capacity ※ L 158
Protection equipment Main & fan motor overload, discharge temperature, reversed phase, water stop relay
Dryer Air dew point at outlet o C 10 (Under application of pressure)
Power consumption ※ kW 2.1 2.5 2.9 3.6 2.9 3.6
Cooling medium R407C
Discharge pipe diameter ※ R 2
WidthxLengthxHeight(Body) ※ mm 1990x1200x1700 2543x1200x1700 3338x1470x1700
Total mass(Dry state)(Dryer less) kg 1500[1350] 1800[1550] 2400[2200]
Noise level dB. A 65 66 67
WidthxLengthxHeight(Body)
Dryer less
mm 1550x1200x1700 1800x1200x1700 2595x1470x1700
  • ◎ Coolant volume (Water temperature 32 o C)) 55kW: 80 L/min 7.5kW: 110 L/min
  • *4=3-phase squirrel cage 2P, open drip proof type

100kW~150kW

Model Z1005AS Z1006AS Z1005ASH Z1006ASH
Items Unit
Delivered air pressure ※ MPa
(kg/cm 2 )
0.7(7.1)
Free air delivery ※ m 3 /min 19.0 18.2 19.0 18.2
Intake air pressure & temperature Atmospheric pressure (0 to 40 o C)
Delivery air temperature about degree C (degF) Less than ambient temp. +15 o C
Capacity control method Power-saving AUCS Automatic start/stop selection
Main motor power kW 100
Power source voltage 50/60Hz,V 380 400 415 380 440 3000 3300
Motor type Three phase squirrel cage type electric motor. Attached with flange leg, 2P totally-enclosed external.
Starter 3 contactors, Y- Reactor
Drive system Direct coupled motor
Cooling system Air-cooling
Fan motor power KW 5.5
The first time Oil fill ration L 80 100
Chamber capacity L 378
Protection equipment Main & fan motor overload, discharge temperature
Discharge pipe diameter R 3B flange
WidthxLengthxHeight(Body) mm 2860x1350x1900 Reactor per unit
2860x1350x1900
Total mass(Dry state)
(Reactor unit)
kg 2750 2750(500)
Noise level dB. A 78
Model Z1005WS Z1006WS Z1005WSH Z1006WSH
Items Unit
Delivered air pressure ※ MPa
(kg/cm 2 )
0.7(7.1)
Free air delivery ※ m 3 /min 19.0 18.2 19.0 18.2
Intake air pressure & temperature Atmospheric pressure (0 to 40 o C)
Delivery air temperature about degree C (degF) Less than coolant inlet temp. +10 o C
Capacity control method Power-saving AUCS Automatic start/stop selection
Main motor power kW 100
Power source voltage 50/60Hz,V 380 400 415 380 440 3000 3300
Motor type Three phase squirrel cage type electric motor. Attached with flange leg, 2P totally-enclosed external.
Starter 3 contactors, Y- Reactor
Drive system Direct coupled motor
Cooling system Water-cooling
Fan motor power KW 0.8 0.12
The first time Oil fill ration L 80 100
Chamber capacity L 378
Protection equipment Main & fan motor overload, discharge temperature, Water stop relay
Discharge pipe diameter R 3B flange
WidthxLengthxHeight(Body) mm 2860x1350x1750 Reactor per unit
2860x1350x1750
Total mass(Dry state)
(Reactor unit)
kg 2350 2350(500)
Noise level dB. A 74
Model Z1505WS Z1506WS Z1505WSH Z1506WSH
Items Unit
Delivered air pressure ※ MPa
(kg/cm 2 )

0.7(7.1)

Free air delivery ※ m 3 /min 27.0 26.0 27.0 26.0
Intake air pressure & temperature Atmospheric pressure (0 to 40 o C)
Delivery air temperature about degree C (degF) Less than coolant inlet temp. +10 o C
Capacity control method Power-saving AUCS Automatic start/stop selection
Main motor power kW 150
Power source voltage 50/60Hz,V 380 400 415 380 440 3000 3300
Motor type Three phase squirrel cage type electric motor. Attached with flange leg, 2P totally-enclosed external.
Starter 3 contactors, Y- Reactor
Drive system Direct coupled motor
Cooling system Water-cooling
Fan motor power KW 0.8 0.12 0.08 0.12
The first time Oil fill ration L 100
Chamber capacity L 378
Protection equipment Main & fan motor overload, discharge temperature, Water stop relay
Discharge pipe diameter R 3B flange
WidthxLengthxHeight(Body) mm 2860x1350x1750 Reactor per unit
2860x1350x1750
Total mass(Dry state)
(Reactor unit)
kg 3050
Noise level dB. A 74
  • ◎ Coolant volume (Entrance temperature 32 o C) 100kW:130 L/min 150kW:200 L/min
  • ◎ I hear air-cooling of 150kW (3000V/6000V/50Hz, 3300V/6600V/60Hz) depending on air order.